ACSR Overhead Bare Conductor Grosbeak 636MCM (26/7) ASTM B232/232M

 China ACSR Overhead Bare Conductor Grosbeak 636MCM (26/7) ASTM B232/232M supplier

ACSR Overhead Bare Conductor Grosbeak 636MCM (26/7) ASTM B232/232M image

Get a Quote Email to us

ACSR conductor Grosbeak 636MCM (26/7) Overhead bare conductor ASTMB232/232M

Application:

ACSR conductor Grosbeak 636MCM (26/7) Overhead bare conductor ASTMB232/232M are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables.

ACSR conductor Grosbeak 636MCM (26/7) Overhead bare conductor ASTMB232/232M Electrical properties:

density@20ºC Aluminium: 2.703 kg/dm
Galvanised Steel: 7.80 kg/dm
Temperature Coefficient@20°C Aluminium: 0.00403 (°C)
resistivity@20°C Aluminium: Should not exceed 0.028264

linear Expansivity

Aluminium: 23 x10 (°C)
Galvanised Steel: 11.5 x10 (1/°C)

Service conditions:

Ambient Temperature -5°C – 50°C
Wind Pressure 80 – 130kg/m
Seismic Acceleration 0.12 – 0.05g
Isokeraunic level 10 – 18
relative Humidity 5 – 100%

ACSR conductor Grosbeak 636MCM (26/7) Overhead bare conductor ASTMB232/232M other features:

Numbers of Wires Modules of Elasticity Coeficient of linear Expansion
AL STEEL Kg/mm2 Lb/in2 1/Cº 1/Fº
6 1 81 11.5 x106 19.1 x10-6 10.6 x10-6
6 7 77 11.0 x106 19.8 x10-6 11.0 x10-6
12 7 107 15.2 x106 15.3 x10-6 8.5 x10-6
18 1 67 9.5 x106 21.2 x10-6 11.8 x10-6
24 7 74 10.5 x106 19.6 x10-6 10.9 x10-6
26 7 77 10.9 x106 18.9 x10-6 10.5 x10-6
28 7 79 11.2 x106 18.4 x10-6 10.2 x10-6
30 7 82 11.6 x106 17.8 x10-6 9.9 x10-6
30 19 80 11.4 x106 18.0 x10-6 10.0 x10-6
32 19 82 11.7 x106 17.5 x10-6 9.7 x10-6
54 7 70 9.9 x106 19.3 x10-6 10.7 x10-6
54 19 68 9.7 x106 19.4 x10-6 10.8 x10-6

ACSR conductor Grosbeak 636MCM (26/7) Overhead bare conductor ASTMB232/232M CONSTRUCTION PARAMETERS

Code Gage
AWG
or MCM
Nominal Cross
Section
(mm²)
Threading:
of wires x
Nominal
Diameter
(mm)
Nominal
External
Diameter
(mm)
Nominal Net Weight
(kg/km)
Load
Before
Rupture
(kN)
Current
Carryng
Capacity
Maximum
Electrical
Resistance
20ºC
(Ohm/km)
Aluminun Total Aluminun Steel Aluminun Steel Total
Duck 605 30,655 3,463 54×2,69 7×2,69 2,420 8,493 3,102 11,595 1,194 735 94,505
Peacock 605 30,655 3,459 24×4,03 7×2,69 2,419 8,481 3,109 11,590 9,588 740 94,505
Squab 605 30,655 3,556 26×3,87 7×3,01 2,451 8,472 3,890 12,362 1,081 745 94,505
Swift 636 32,226 3,320 36×3,38 1×3,38 2,366 8,905 700 9,605 6,068 745 89,460
King Bird 636 32,226 3,409 18×4,78 1×4,78 2,390 8,905 1,393 10,298 6,967 750 89,460
Rook 636 32,226 3,650 24×4,14 7×2,76 2,484 8,952 3,273 12,225 1,011 765 89,898
Grosbeak 636 32,226 3,743 26×3,97 7×3,09 2,515 8,916 4,101 13,017 1,119 775 89,898
Egret 636 32,226 3,961 30×3,70 19×2,22 2,590 8,960 5,753 14,713 1,405 775 90,117
Flamingo 6,666 33,776 3,810 24×4,23 7×2,82 2,538 9,345 3,413 12,758 1,055 790 85,772
Gannet 6,666 33,776 3,932 26×4,07 7×3,16 2,575 9,373 4,288 13,661 1,173 795 85,772
Starling 7,155 36,254 4,210 26×4,21 7×3,28 2,668 1003 4,616 1465 1,259 835 79,910
Redwing 7,155 36,254 4,445 30×3,92 19×2,35 2,743 1006 6,449 1651 1,537 835 802

ACSR conductor Grosbeak 636MCM (26/7) Overhead bare conductor ASTMB232/232M physical pictures:

Why choose us

  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007
  • Registered capital of $30 million and factory covers an area of 60,000㎡
  • Advanced test equipment and procedures, 100% inspection before factory
  • Enough stocks and the higest efficient shipping time guarranteed
  • Professional pre-sales and after-sales services provided

We are China ACSR Overhead Bare Conductor Grosbeak 636MCM (26/7) ASTM B232/232M manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION