All Aluminium conductor steel reinforced as per ASTM A 399
All Aluminium conductor steel reinforced as per ASTM A 399 image
Brand Name :
Litong Global
Model Number :
LT-170622
Certification :
ISO9001-2008,CCC
Place of Origin :
Anhui,China
MOQ :
1000m
Price :
discuss
Supply Ability :
50kms/day
Packaging Details :
standard export packing on drum
Model NO. :
AAAC Conductor
Type :
Bare
Conductor Type :
Stranded
Application :
Overhead
Conductor Material :
Aluminum Alloy
Sheath Material :
Bare
Insulation Material :
Bare
Material Shape :
Round Wire
OEM :
Acceptable
Specification :
1/0 2/0 3/0 4/0
Code word | Conductor size | Stranding | Section area | Diameter of conductor |
Linear Mass | Nominal Breaking Load |
Maximum DC Resistance at 20℃ |
AWG MCM | No./mm | mm2 | mm | kg/km | kgf | Ω/km | |
Alton | 4 | 7/1.96 | 21.14 | 5.89 | 57.89 | 685 | 1.5860 |
48.69(4) | 7/2.12 | 24.67 | 6.35 | 67.56 | 799 | 1.3557 | |
Amas | 2 | 7/2.47 | 33.65 | 7.42 | 92.14 | 1091 | 0.9987 |
77.47(2) | 7/2.67 | 39.26 | 8.02 | 107.50 | 1275 | 0.8547 | |
Azusa | 1/0 | 7/3.12 | 53.49 | 9.35 | 146.50 | 1733 | 0.6259 |
123.3(1/0) | 7/3.37 | 62.46 | 10.11 | 171.00 | 2019 | 0.5365 | |
Anahelm | 2/0 | 7/3.50 | 67.45 | 10.52 | 184.70 | 2090 | 0.4974 |
155.4(2/0) | 7/3.78 | 78.75 | 11.35 | 215.16 | 2447 | 0.4264 | |
Amherst | 3/0 | 7/3.93 | 85.00 | 11.79 | 232.70 | 2641 | 0.3945 |
195.7(3/0) | 7/4.25 | 99.20 | 12.75 | 271.50 | 3079 | 0.3373 | |
Altiance | 4/0 | 7/4.42 | 107.20 | 13.26 | 293.70 | 3334 | 0.3119 |
246.9(4/0) | 7/4.77 | 125.10 | 14.30 | 342.60 | 3885 | 0.2678 | |
250.0 | 19/2.91 | 126.70 | 14.58 | 346.90 | 3977 | 0.2651 |
AAAC-ASTM Standard Continue Table
Code word | Conductor size | Stranding | Section area | Diameter of conductor |
Linear Mass |
Nominal Breaking Load |
Maximum DC Resistance at 20℃ |
AWG MCM | No./mm | mm2 | mm | kg/km | kgf | Ω/km | |
Butte | 300.0 | 19/3.19 | 152.10 | 15.89 | 418.60 | 4772 | 0.2206 |
312.8 | 19/3.26 | 158.50 | 16.31 | 434.00 | 4976 | 0.2112 | |
Canton | 350.0 | 19/3.46 | 177.30 | 17.25 | 485.50 | 5333 | 0.1886 |
394.5 | 19/3.66 | 199.00 | 18.31 | 547.40 | 6016 | 0.1676 | |
Calro | 400.0 | 19/3.69 | 202.70 | 18.44 | 555.10 | 6098 | 0.1649 |
450.0 | 19/3.91 | 228.00 | 19.56 | 624.40 | 6862 | 0.1468 | |
465.4 | 19/3.98 | 235.80 | 19.89 | 645.70 | 7097 | 0.1431 | |
Darien | 500.0 | 19/4.12 | 253.40 | 20.60 | 693.60 | 7617 | 0.1322 |
550.0 | 37/3.10 | 278.70 | 21.67 | 762.90 | 8555 | 0.1200 | |
559.5 | 19/4.36 | 283.50 | 21.79 | 776.30 | 8525 | 0.1181 | |
Elgin | 600.0 | 37/3.23 | 304.00 | 22.63 | 832.00 | 9330 | 0.1105 |
650.0 | 37/3.37 | 329.40 | 23.57 | 909.80 | 10105 | 0.1015 | |
Flint | 652.4 | 19/4.71 | 330.60 | 23.55 | 970.60 | 9942 | 0.1012 |
700.0 | 37/3.49 | 354.50 | 24.46 | 910.60 | 10401 | 0.09464 | |
740.8 | 37/3.59 | 375.40 | 25.15 | 1028 | 11013 | 0.08944 | |
750.0 | 37/3.62 | 380.20 | 25.32 | 1041 | 11216 | 0.08796 | |
Greeley | 800.0 | 37/3.73 | 405.40 | 26.14 | 1109 | 11930 | 0.08285 |
900.0 | 37/3.96 | 456.30 | 27.74 | 1249 | 13460 | 0.07351 | |
927.2 | 37/4.02 | 469.80 | 28.14 | 1287 | 13868 | 0.07133 | |
1000 | 37/4.18 | 506.70 | 29.24 | 1388 | 14887 | 0.06597 | |
1077.4 | 61/3.38 | 483.40 | 30.42 | 1496 | 15907 | 0.06120 | |
1165.1 | 61/3.51 | 523.70 | 31.59 | 1617 | 17233 | 0.05675 | |
1250 | 61/3.63 | 633.30 | 32.67 | 1733 | 18354 | 0.05306 | |
1259.6 | 61/3.65 | 564.00 | 32.85 | 1748 | 18558 | 0.05248 | |
1348.8 | 61/3.78 | 604.20 | 34.02 | 1872 | 19884 | 0.04893 | |
1439.2 | 61/3.90 | 644.50 | 35.1 | 1997 | 21209 | 0.04597 | |
1500.0 | 61/3.98 | 760.00 | 35.82 | 2081 | 22127 | 0.04414 | |
1750.0 | 61/4.30 | 886.70 | 38.7 | 2429 | 25798 | 0.03781 |
AAAC-BS Standard
Code word | Conductor size | Stranding | Section area | Diameter of conductor |
Linear Mass |
Nominal Breaking Load |
Maximum DC Resistance at 20℃ |
AWG MCM | No./mm | mm2 | mm | kg/km | kgf | Ω/km | |
Box | 15 | 7/1.85 | 18.82 | 5.55 | 51 | 537 | 1.7495 |
Acacia | 20 | 7/2.08 | 23.79 | 6.24 | 65 | 680 | 1.3840 |
Almond | 25 | 7/2.34 | 30.10 | 7.02 | 82 | 861 | 1.0934 |
Cedar | 30 | 7/2.54 | 35.47 | 7.62 | 97 | 1014 | 0.9281 |
35 | 7/2.77 | 42.18 | 8.31 | 115 | 1205 | 0.7804 | |
Fir | 40 | 7/2.95 | 47.84 | 8.85 | 131 | 1367 | 0.6880 |
Hazel | 50 | 7/3.30 | 59.87 | 9.9 | 164 | 1711 | 0.55498 |
Pine | 60 | 7/3.61 | 71.65 | 10.83 | 196 | 2048 | 0.4594 |
70 | 7/3.91 | 84.05 | 11.73 | 230 | 2402 | 0.3917 | |
Willow | 75 | 7/4.04 | 89.73 | 12.12 | 245 | 2565 | 0.3669 |
AAAC-BS Standard Continue Table
Code word | Conductor size | Stranding | Section area | Diameter of conductor |
Linear Mass | Nominal Breaking Load |
Maximum DC Resistance at 20℃ |
AWG/MCM | No./mm | mm2 | mm | kg/km | kgf | Ω/km | |
80 | 7/4.19 | 96.52 | 12.57 | 264 | 2758 | 0.3441 | |
90 | 7/4.44 | 108.00 | 13.32 | 298 | 3112 | 0.3023 | |
Oak | 100 | 7/4.65 | 118.90 | 13.95 | 325 | 3398 | 0.2769 |
100 | 19/2.82 | 118.70 | 14.1 | 326 | 3393 | 0.2787 | |
Mulberry | 125 | 19/3.18 | 150.90 | 15.9 | 415 | 4312 | 0.2192 |
Ash | 150 | 19/3.48 | 180.70 | 17.4 | 497 | 5164 | 0.1831 |
Elm | 175 | 19/3.76 | 211.00 | 18.8 | 580 | 6030 | 0.1568 |
Poplar | 200 | 37/2.87 | 239.40 | 20.09 | 659 | 8841 | 0.1385 |
225 | 37/3.05 | 270.30 | 21.35 | 744 | 7724 | 0.1227 | |
Sycamore | 250 | 37/3.22 | 303.20 | 22.54 | 835 | 8864 | 0.1093 |
Upas | 300 | 37/3.53 | 362.10 | 24.71 | 997 | 10350 | 0.09156 |
Walnut | 350 | 37/3.81 | 421.80 | 26.67 | 1162 | 12053 | 0.07860 |
Yew | 400 | 37/4.06 | 479.00 | 28.42 | 1319 | 13685 | 0.06921 |
Totara | 425 | 37/4.14 | 498.10 | 28.98 | 1372 | 14233 | 0.06656 |
Rubus | 500 | 61/3.50 | 586.90 | 31.5 | 1620 | 16771 | 0.05662 |
Araucaria | 700 | 61/4.14 | 821.10 | 37.26 | 2266 | 23450 | 0.04047 |
AAAC-DIN Standard
Conductor size |
Alloy area | Number of wires |
Diameter of wire | Overall diameter of conductor |
Linear Mass | Nominal Breaking Load |
Maximum DC Resistance at 20 ℃ |
mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
AAAC-IEC Standard
Code name | Area/ mm2 |
No.of wires | Diameter/mm | Linear Mass kg/km |
Nominal Breaking Load kN |
Maximum DC Resistance at 20℃ Ω/km |
|
Wire | Cond. | ||||||
16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
25 | 28.8 | 7 | 2.29 | 6.86 | 78.7 | 8.49 | 1.1453 |
40 | 46.0 | 7 | 2.89 | 8.68 | 125.9 | 13.58 | 0.7158 |
63 | 72.5 | 7 | 3.63 | 10.9 | 198.3 | 21.39 | 0.4545 |
100 | 115 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 0.2877 |
125 | 144 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 0.2302 |
160 | 184 | 19 | 3.51 | 17.6 | 506.1 | 54.32 | 0.1798 |
200 | 230 | 19 | 3.93 | 19.6 | 632.7 | 67.91 | 0.1439 |
250 | 288 | 19 | 4.39 | 22.0 | 790.8 | 84.88 | 0.1151 |
315 | 363 | 37 | 3.53 | 24.7 | 998.9 | 106.95 | 0.0916 |
400 | 460 | 37 | 3.98 | 27.9 | 1268.4 | 135.81 | 0.0721 |
450 | 518 | 37 | 4.22 | 29.6 | 1426.9 | 152.79 | 0.0641 |
500 | 575 | 37 | 4.45 | 31.2 | 1585.5 | 169.76 | 0.0577 |
560 | 645 | 61 | 3.67 | 33.0 | 1778.4 | 190.14 | 0.0516 |
630 | 725 | 61 | 3.89 | 35.0 | 2000.7 | 213.90 | 0.0458 |
710 | 817 | 61 | 4.13 | 37.2 | 1154.8 | 241.07 | 0.0407 |
800 | 921 | 61 | 4.38 | 39.5 | 2540.6 | 271.62 | 0.0361 |
900 | 1036 | 91 | 3.81 | 41.8 | 2861.1 | 305.58 | 0.0321 |
1000 | 1151 | 91 | 4.01 | 44.1 | 3179.0 | 339.53 | 0.0289 |
1120 | 1289 | 91 | 4.25 | 46.7 | 3560.5 | 380.27 | 0.0258 |
1250 | 1439 | 91 | 4.49 | 49.4 | 3973.7 | 424.41 | 0.0231 |
Code name | Area/ mm2 |
No.of wires | Diameter/mm | Linear Mass kg/km |
Nominal Breaking Load kN |
Maximum DC Resistance at 20℃ Ω/km |
|
Wire | Cond. | ||||||
16 | 18.6 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 29.0 | 7 | 2.30 | 6.90 | 79.5 | 9.44 | 1.1453 |
40 | 46.5 | 7 | 2.91 | 8.72 | 127.1 | 15.10 | 0.7158 |
63 | 73.2 | 7 | 3.65 | 10.9 | 200.2 | 23.06 | 0.4545 |
100 | 116 | 19 | 2.79 | 14.0 | 319.3 | 37.76 | 0.2877 |
125 | 145 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
160 | 186 | 19 | 3.53 | 17.6 | 511.0 | 58.56 | 0.1798 |
200 | 232 | 19 | 3.95 | 19.7 | 638.7 | 73.20 | 0.1439 |
250 | 290 | 19 | 4.41 | 22.1 | 798.4 | 91.50 | 0.1151 |
315 | 366 | 37 | 3.55 | 24.8 | 1008.4 | 115.29 | 0.0913 |
400 | 465 | 37 | 4.00 | 28.0 | 1280.5 | 146.40 | 0.0721 |
450 | 523 | 37 | 4.24 | 29.7 | 1440.5 | 164.70 | 0.0641 |
500 | 581 | 37 | 4.47 | 31.3 | 1600.6 | 183.00 | 0.0577 |
560 | 651 | 61 | 3.69 | 33.2 | 1795.3 | 204.96 | 0.0516 |
63
We are China All Aluminium conductor steel reinforced as per ASTM A 399 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price. Tags: AAC and AAACFAST AND RELIABLE SERVICE FOR YOUR PROJECTContact our trained experts today to find your perfect power solution. ASK A QUESTION© 2020 Galaxy Electric Country Code Sitemap Cable |