Grey Color Overhead Line Conductor Variable Steel Core Stranding High Precision

 China Grey Color Overhead Line Conductor Variable Steel Core Stranding High Precision supplier

Grey Color Overhead Line Conductor Variable Steel Core Stranding High Precision image

Get a Quote Email to us

Brand Name :
TANO CABLE

Model Number :
AACSR Conductor

Certification :
ISO

Place of Origin :
CHINA

MOQ :
2000 meters

Price :
Negotiable

Payment Terms :
L/C, T/T

Supply Ability :
200KM Per Month

Delivery Time :
7-30 days

Packaging Details :
By wooden drum/reel, steel-wooden drum/reel, steel drum/reel with strong protection to suit for the long-distance delivery.

Color :
Grey

Packing :
Wooden drums

Standard :
GB/T 1179

Application :
Overhead

Name :
Aluminium alloy steel core aluminium strand

Material :
All aluminum alloy and steel wire

AACSR Conductor 95 / 15 GB / T Standard Aluminium alloy steel core aluminium strand

Production Description of AACSR conductor
Conductor(AAAC) bear conductor meets or exceeds the following ASTM Specifications:
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purpose.
B-399 Concentrical-Lay-Stranded 6201-T81 Aluminum Alloy Conductors

Application of AACSR conductor

Used as bare overhead transmission cable and as primary and secondary distribution cable. AACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Standard of AACSR conductor

ASTM B711, IEC 61089, AS 3607, GB/T 1179

Construction of AACSR conductor

AACSR is a concentrically stranded conductor composed of one or more layers of 6201 -T81 aluminum alloy wire stranded with a high-strength coated steel core. The core may be single wire or stranded depending on the size.
The proportions of aluminum alloy and steel can be varied to obtain the relation between currentcarrying capacity and mechanical strength best suited to each application.
Core wire for AACSR is available with Class A, B or C galvanizing; "aluminized" aluminum coated (AZ): or aluminum clad (AW).
Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.

Construction Parameters

Standard sizes to GB/T 1179—2008

Nominal section aluminum alloy/steel Areas/mm2 Stranding Number & Wire Diameter Diameter/mm Linear. mass/ (kg/km) D.C resistance (20 V)/ (O/km)
Alum Steel Total Al St Core Cond
10/2 10. 60 1. 77 12.37 6/1. 50 1/1. 50 1. 50 4. 50 42.8 3.144 4
16/3 16. 13 2. 69 18.82 6/1. 85 1/1.85 1.85 5. 55 65.1 2.067 1
25/4 25.36 4. 23 29.59 6/2. 32 1/2. 32 2. 32 6. 96 102.4 1.314 4
35/6 34. 86 5. 81 40.67 6/2.72 1/2.72 2.72 8. 16 140.8 0. 956 3
50/8 48.25 8. 04 56.3 6/3.2 1/3.2 3.2 9. 60 194.8 0. 690 9
50/30 50.73 29.59 80.32 12/2. 32 7/2.32 6.96 11.6 371. 1 0. 661 4
70/10 68. 05 11.34 79.39 6/3. 80 1/3.8 3.8 11.4 274.8 0.489 9
70/40 69. 73 40. 67 110.4 12/2.72 7/2.72 8. 16 13. 6 510.2 0.481 2
95/15 94. 39 15.33 109. 73 26/2. 15 7/1.67 5.01 13. 6 380.2 0. 355 4
95/55 96. 51 56.3 152.81 12/3. 20 7/3. 20 9.6 16 706. 1 0.347 7
120/7 118.89 6. 61 125. 50 18/2. 90 1/2. 90 8. 70 14. 5 378.5 0.281 5
120/20 115. 67 18.82 134.49 26/2. 38 7/1.85 5. 55 15. 1 466.1 0. 290 0
120/70 122. 15 71.25 193.4 12/3. 60 7/3. 60 10.8 18 893.7 0.274 7
150/8 144.76 8. 04 152.81 18/3.2 1/3.2 3. 20 16 460.9 0.231 2
150/25 148.86 24.25 173.11 26/2. 70 7/2.1 6.3 17.1 600.1 0.225 4
185/10 183.22 10.18 193.4 18/3.6 1/3.6 3. 60 18 583. 3 0. 182 6
210/10 204.14 11. 34 215.48 18/3.8 1/3.8 3. 80 19 649. 9 0. 163 9
210/35 211.73 34.36 246.09 26/3. 22 7/2.5 7.5 20.4 852.5 0. 158 5
240/30 244. 29 31.67 275. 96 24/3. 60 7/2.4 7.2 21.6 920.7 0. 137 2
240/40 238.84 38. 90 277.74 26/3. 42 7/2. 66 7. 98 21.7 962.8 0. 140 5
300/20 303.42 20.91 324. 32 45/2. 93 7/1. 95 5.85 23.4 1 000.8 0. 110 6
300/50 299.54 48.82 348.37 26/3.83 7/2.98 8. 94 24.3 1 207.7 0.112 0
300/70 305.36 71.25 376.61 30/3. 60 7/3. 60 10.8 25.2 1 399. 6 0. 109 9
400/25 391.91 27.1 419.01 45/3.33 7/2.22 6. 66 26. 6 1 293. 5 0.085 7
400/50 399.72 51.82 451. 54 54/3.07 7/3.07 9. 21 27.6 1 509.3 0. 084 1
400/95 407.75 93.27 501.02 30/4. 16 19/2.5 12.5 29. 1 1 856. 7 0.082 3
500/35 497.01 34.36 531. 37 45/3. 75 7/2.5 7.5 30. 0 1 640. 3 0.067 5
500/65 501. 88 65.06 566.94 54/3.44 7/3.44 10.3 31 1 895.0 0.067 0
630/45 623.45 43. 10 666. 55 45/4.2 7/2. 80 8.4 33. 6 2 057.6 0.053 8
630/80 635. 19 80.32 715.51 54/3. 87 19/2.32 11.6 34.8 2 384. 7 0. 052 9
800/55 814. 30 56.3 870. 60 45/4. 80 7/3.2 9. 60 38.4 2 687. 5 0.041 2
800/100 795. 17 100.88 896.05 54/4. 33 19/2. 60 13 39 2 987.8 0.042 3
1000/45 1 002.27 43.1 1 045.38 72/4. 21 7/2.8 8.4 42. 1 3 106. 8 0.033 5
1000/125 993. 51 125. 50 1 119.01 54/4. 84 19/2. 90 14.5 43.5 3 728. 9 0.033 8

Packing&Shipping of AACSR conductor

Details :

1) Packing length:100 to 1,000m reeled in carton drum or according to customers'requirement

2) Outer packing: wooden case, carton box

3) Other packing requirement according to customer's request.

FAQ

1.what is our payment term?

Our payment term is usually T/T 30% in advanced, the balance before picking up the goods or L/C at sight.

2.what is the lead time?

The lead time usually is 10 – 30 working days.

3.what is the package of the cable?

The package is usually wooden drum or steel wooden drum or coil.also according to customer’s requirment.

4.Could we provide the free sample for customer?

Sure, we provide the free sample for customer to checking.

We are China Grey Color Overhead Line Conductor Variable Steel Core Stranding High Precision manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION