multi-core Low Voltage Power Cable 0.6/1 kV PVC Insulation PVC Sheathed Unarmoured and armoured

 China multi-core Low Voltage Power Cable 0.6/1 kV PVC Insulation PVC Sheathed Unarmoured and armoured supplier

multi-core Low Voltage Power Cable 0.6/1 kV PVC Insulation PVC Sheathed Unarmoured and armoured image

Get a Quote Email to us

Brand Name :
Chengtiantai Cable

Model Number :
NYY-3C+1

Certification :
CE, CB

Place of Origin :
Shenzhen, Mainland China

MOQ :
500 m

Price :
On Request

Payment Terms :
L/C, T/T

Delivery Time :
15 working days after payments

Packaging Details :
Steel Wooden Drum

Nominal Voltage :
0.6/1 kV

Core Insulation :
PVC

No. of Conductor :
from 1 to 5

Outer Sheath :
PVC

Conductor Material :
Bare Copper Class 2

Manufacturer :
Shenzhen Chengtiantai

PVC Insulated multi-core Cable

Copper Conductor, PVC Insulated & Sheathed

APPLICATIONS:

Power cables for energy supply are installed in open air, in underground, indoors, in cable ducts, power stations, residental connections and street lighting as well as in subscriber networks, where mechanical damages are not be expected.

STANDARDS

International: IEC 60502-1
National:GB/ T 12706.1-2008

CONSTRUCTION:

1. CONDUCTOR– Bare copper conductor, Class 2 to IEC 60228

2. INSULATION
– PVC Compound

3. FILLER

PP filler

4. INNER SHEATH(in case of armoured cable)

– PVC Compound

5. ARMOUR

Two steel tape

6. OUTER SHEATH :
– PVC Compound

Sheath colour :
– Black

*Note: when required for a particular application, other colors are available.

Electrical Characteristics

Rated Voltage Uo/U 0.6/1 kV
Maximum operating voltage 1.2 kV
Frequence 50 Hz
Test voltage : 3500 V

Usage Characteristics

Permissible operating temperature at conductor 70°C
short circuit temperature ( duration max. 5 s) 160 °C
Minimum installation temperature should not be lower than 0°C
Max. conductor permissible tensile stress 50 N/mm²
Minimum bending radius 12 x cable Ø

2 CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
2×1.5 0.8 1.8 10.5 129 19 25 12.1
2×2.5 0.8 1.8 11.3 158 26 34 7.41
2×4.0 1.0 1.8 13.0 221 35 44 4.61
2×6.0 1.0 1.8 14.0 274 44 56 3.08
2×10 1.0 1.8 16.7 378 60 76 1.83
2×16 1.0 1.8 18.8 519 80 100 1.15
2×25 1.2 1.8 22.6 758 107 129 0.73
2×35 1.2 1.8 19.2 978 131 157 0.52
2×50 1.4 1.8 22.0 1217 152 187 0.39
2×70 1.4 1.9 24.3 1613 194 233 0.27
2×95 1.6 2.0 27.0 2157 238 278 0.19
2×120 1.6 2.1 30.0 2658 275 318 0.15
2×150 1.8 2.2 33.0 3296 318 357 0.12
2×185 2.0 2.4 36.8 4027 366 404 0.10

2 CORE CABLE (ARMOURED) Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
2×4 1.0 1.8 16.3 388 34 44 4.61
2×6 1.0 1.8 17.3 454 43 53 3.08
2×10 1.0 1.8 20.0 589 58 70 1.83
2×16 1.0 1.8 22.0 748 77 92 1.15
2×25 1.2 1.8 25.5 1029 104 122 0.73
2×35 1.2 1.8 27.8 1276 129 149 0.52
2×50 1.4 1.8 26.5 1487 146 171 0.39
2×70 1.4 1.9 30.3 2178 188 214 0.27
2×95 1.6 2.1 34.2 2800 240 267 0.19
2×120 1.6 2.2 36.5 3365 274 306 0.15
2×150 1.8 2.4 40.0 4059 316 346 0.12
2×185 2.0 2.5 43.8 4984 368 394 0.10

3 CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
3×1.5 0.8 1.8 11 154 17 22 12.1
3×2.5 0.8 1.8 11.9 194 22 29 7.41
3×4.0 1.0 1.8 13.8 274 29 38 4.61
3×6.0 1.0 1.8 14.9 348 37 47 3.08
3×10 1.0 1.8 17.6 529 52 65 1.83
3×16 1.0 1.8 19.9 740 68 85 1.15
3×25 1.2 1.8 23.7 1058 91 110 0.73
3×35 1.2 1.8 26.1 1382 112 134 0.52
3×50 1.4 1.8 26.4 1760 133 159 0.39
3×70 1.4 2.0 29.8 2364 171 199 0.27
3×95 1.6 2.1 33.8 3158 209 237 0.19
3×120 1.6 2.2 36.7 3921 242 271 0.15
3×150 1.8 2.3 40.2 4868 282 305 0.12
3×185 2.0 2.5 45.6 5952 329 346 0.10
3×240 2.2 2.7 51.7 7713 392 400 0.08
3×300 2.4 2.9 56.1 10004 450 462 0.06

3 CORE CABLE (ARMOURED) Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
3×4 1.0 1.8 17.0 450 29 36 4.61
3×6 1.0 1.8 18.1 538 37 45 3.08
3×10 1.0 1.8 20.8 745 50 60 1.83
3×16 1.0 1.8 23.1 983 66 79 1.15
3×25 1.2 1.8 26.9 1344 90 105 0.73
3×35 1.2 1.8 29.3 1702 111 127 0.52
3×50 1.4 1.9 31.2 2344 129 148 0.39
3×70 1.4 2.0 34.4 3017 165 185 0.27
3×95 1.6 2.2 38.6 3913 206 221 0.19
3×120 1.6 2.3 41.7 4741 242 261 0.15
3×150 1.8 2.5 45.5 5790 281 296 0.12
3×185 2.0 2.6 51.0 7013 328 337 0.10
3×240 2.2 2.8 57.3 8930 386 389 0.08
3×300 2.4 3.0 61.5 11350 445 441 0.06

4 CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
4×4 1.0 1.8 14.9 339 30 38 4.61
4×6 1.0 1.8 16.1 436 38 48 3.08
4×10 1.0 1.8 19.3 669 53 66 1.83
4×16 1.0 1.8 21.8 953 70 86 1.15
4×25 1.2 1.8 26.0 1374 94 112 0.73
4×35 1.2 1.8 28.7 1810 116 135 0.52
4×50 1.4 1.9 29.5 2312 139 161 0.39
4×70 1.4 2.1 33.0 3105 177 202 0.27
4×95 1.6 2.2 38.1 4179 217 240 0.19
4×120 1.6 2.4 41.1 5185 254 274 0.15
4×150 1.8 2.5 45.8 6414 294 309 0.12
4×185 2.0 2.7 50.5 7901 337 346 0.10
4×240 2.2 2.9 55.7 10249 401 403 0.08
4×300 2.4 3.1 63.4 13365 470 459 0.06

4 CORE CABLE (ARMOURED) Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
4×4 1.0 1.8 18.2 529 30 37 4.61
4×6 1.0 1.8 19.3 641 38 46 3.08
4×10 1.0 1.8 22.5 905 53 64 1.83
4×16 1.0 1.8 25.0 1218 71 83 1.15
4×25 1.2 1.8 29.2 1690 94 108 0.73
4×35 1.2 1.9 33.5 2479 117 132 0.52
4×50 1.4 2.0 34.3 2963 140 157 0.39
4×70 1.4 2.2 37.8 3831 178 196 0.27
4×95 1.6 2.4 43.1 5032 219 234 0.19
4×120 1.6 2.5 46.3 6105 255 268 0.15
4×150 1.8 2.6 51.0 7475 294 301 0.12
4×185 2.0 2.8 56.2 9070 333 338 0.10
4×240 2.2 3.0 61.3 11664 397 393 0.08
4×300 2.4 3.2 69.3 15018 464 448 0.06

4 CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
5×4 1.0 1.8 16.2 403 31 39 4.61
5×6 1.0 1.8 17.5 520 39 49 3.08
5×10 1.0 1.8 21.0 811 54 67 1.83
5×16 1.0 1.8 23.8 1156 72 87 1.15
5×25 1.2 1.8 28.5 1778 96 111 0.73
5×35 1.2 1.9 31.3 2348 118 134 0.52
5×50 1.4 2.1 37.0 3129 144 159 0.39
5×70 1.4 2.2 42.0 4357 186 199 0.27
5×95 1.6 2.4 49.1 5953 227 235 0.19
5×120 1.6 2.5 53.6 7298 266 269 0.15
5×150 1.8 2.7 59.3 8947 303 302 0.12
5×185 2.0 2.9 66.0 11144 352 343 0.10
5×240 2.2 3.1 74.6 14327 420 398 0.08
5×300 2.4 3.3 82.6 17823 483 452 0.06

4 CORE CABLE (ARMOURED) Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness
Inner Sheath thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm mm kg / km A A Ω/km
5×4 1.0 0.9 1.8 19.4 606 31 38 4.61
5×6 1.0 0.9 1.8 20.7 739 39 47 3.08
5×10 1.0 0.9 1.8 24.2 1072 55 65 1.83
5×16 1.0 0.9 1.8 27.0 1450 72 85 1.15
5×25 1.2 0.9 1.8 31.9 2143 96 108 0.73
5×35 1.2 0.9 2.0 36.4 3098 119 131 0.52
5×50 1.4 1.2 2.2 41.6 3992 145 156 0.39
5×70 1.4 1.2 2.3 46.8 5356 187 195 0.27
5×95 1.6 1.2 2.5 54.1 7138 225 230 0.19
5×120 1.6 1.4 2.6 58.8 8616 263 274 0.15
5×150 1.8 1.4 2.8 64.7 10429 296 301 0.12
5×185 2.0 1.4 3.0 76.6 12817 335 348 0.10
5×240 2.2 1.4 3.2 80.8 15226 387 409 0.08
5×300 2.4 1.4 3.5 89.0 20062 439 472 0.06
3 +2 CORE PVC INSULATED & SHEATHED POWER CABLE(UNARMOURED)

No.cores x cross-sec. Insulation thickness Sheath thickness Nominal value Outer Ø approx. weight approx. Current ratings in air 30℃ Current ratings buried 20℃
Phase Neutral
mm² mm mm mm mm kg / km A A
3×4+2×2.5 1.0 0.8 1.8 15.3 351 30 38
3×6+2×4.0 1.0 1.0 1.8 17.0 473 38 48
3×10+2×6.0 1.0 1.0 1.8 19.7 691 52 66
3×16+2×10 1.0 1.0 1.8 22.0 1012 69 86
3×25+2×16 1.2 1.0 1.8 26.8 1536 93 111
3×35+2×16 1.2 1.0 1.8 28.9 1872 113 134
3×50+2×25 1.4 1.2 1.9 34.2 2596 141 163
3×70+2×35 1.4 1.2 2.0 38.8 3524 180 203
3×95+2×50 1.6 1.4 2.2 44.4 4776 221 242
3×120+2×70 1.6 1.4 2.3 49.0 6124 258 276
3×150+2×70 1.8 1.4 2.4 53.7 7113 298 310
3×185+2×95 2.0 1.6 2.6 60.0 9046 343 349
3×240+2×120 2.2 1.6 2.8 67.5 11558 408 406
3×300+2×150 2.4 1.8 3.0 75.0 14389 479 462
3 +2 CORE STEEL TAPE ARMOURED POWER CABLE

No.cores x cross-sec. Insulation thickness Sheath thickness Nominal value Outer Ø approx. weight approx. Current ratings in air 30℃ Current ratings buried 20℃
Phase Neutral
mm² mm mm mm mm kg / km A A
3×4+2×2.5 1.0 0.8 1.8 18.5 495 30 37
3×6+2×4.0 1.0 1.0 1.8 20.2 608 38 46
3×10+2×6.0 1.0 1.0 1.8 22.9 834 52 64
3×16+2×10 1.0 1.0 1.8 26.0 1143 70 84
3×25+2×16 1.2 1.0 1.8 30.2 1607 93 108
3×35+2×16 1.2 1.0 1.8 33.5 2060 113 130
3×50+2×25 1.4 1.2 1.9 38.8 2795 142 158
3×70+1×35 1.4 1.2 2.1 43.6 3581 181 199
3×95+2×50 1.6 1.4 2.3 49.4 4676 222 236
3×120+2×70 1.6 1.4 2.4 55.0 5751 258 269
3×150+2×70 1.8 1.4 2.5 59.1 6788 297 303
3×185+2×95 2.0 1.6 2.7 65.6 8371 338 340
3×240+2×120 2.2 1.6 2.9 73.7 10523 404 396
3×300+2×150 2.4 1.8 3.1 81.5 13572 472 450
*Dimensions and specifications may be changed without prior notice.

Conductor Design

Packaging & Delivery

Packaging details :

Delivery :

Steel Wooden Drums Cable Drum In container shipped in 15 days after payment

Cable Drum Data

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

Delivery Port:

Port of Shenzhen Port of Hongkong Port of Guangzhou

Manufacturing Process Of Low Voltage Power Cable ( Unarmored )

1. copper rod 2. wire drawing 3. wire stranding
4.Inner sheath 5. Assembling 6.outer covering Process
7. Sheath Marking 8. Packing 9. cable delivering

Our production in numbers

● Cable production started 1983
35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

100,000 m2 Production area
350 Will-trained employees
● Exported more than 22 countries
2 Manufacturing plant
1 R&D Center

200 Sets Of Testing Equipment

100 Testing Items
8 workshop
40 wire drawing machines
10 bunching machines
28 Extruder system
42 stranding machines
10 Braiding machines

Some great shots of our manufactering plant

Mannufacturing plant R&D Building Bird's eye view of the plant
MV Power Cable Workshop Cable Reels Waiting to be shipped out Shipping
Shenzhen chengtiantai cable operates certified management systems compliant with:
Certificat Information

ISO 9001:2008

quality management systems

Certificat ISO 9001:2008
– Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

ISO 14001:2004

environmental management systems

Certificat ISO 14001:2004

– Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

OHSAS 18001:2007

assessment specification for occupational health & safety management systemsenvironmental management systems

Certificat OHSAS 18001:2007

– Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

Customer services:

RECOMMENDED ORDERING PARAMETERS

CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 – International or Special Standard. (Alternatively, the precise usage of the cable.)
2 – Rated voltage.
3 – Copper or Aluminium conductors.
4 – Size of each conductor.
5 – Insulation material : XLPE or others.
6 – Number and identification of conductors.
7 – Other requirements.
8 – Packing.
9 – Required delivery time.
10 – Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : [email protected]
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

WARRANTY

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

We are China multi-core Low Voltage Power Cable 0.6/1 kV PVC Insulation PVC Sheathed Unarmoured and armoured manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION