name :
Overhead ABC cable

Material :
Aluminum, Aluminum alloy

Insulation material: :
PVC XLPE Rubber

Type :
low voltage

Standard :
ASTM BS DIN IEC GB

Rated voltage :
1-35 KV

Price :
Negotiation

Packaging Details :
Standard export package

Delivery Time :
15-20 working days or Negotiation

Payment Terms :
T/T, L/C, D/P, West Union, Paypal, Secure Payments

Power Transmission Line Electric Cable Overhead ABC cable

Model Number: OEM

Material: Aluminum, Aluminum alloy

Type:low voltage

Rated voltage: 1-35KV

Standard: ASTM BS DIN IEC GB

Insulation material: PVC XLPE Rubber

MOQ: negotiable

Packing: negotiable

Description:

Aluminum conductor PVC insulated ABC cable

APPLICATIONS:
Covered line Wire is used primarily for 600v overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
CONSTRUCTION:
The conductors are 1350-H19 Aluminum Wire ,6201-T81 Aluminum Alloy or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene(HDPE) or cross-linked polyethylene(XLPE).

Duplex Service Drop—Aluminum Conductor
APPLICATIONS:
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

Triplex Service Drop—Aluminum Conductor
APPLICATIONS:
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
Quadruplex Service Drop—Aluminum Conductor
APPLICATIONS:
Used to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR. Conductors are manufactured with ridges for phase identification (one conductor one ridge, one conductor two ridges, one conductor plain.)

STANDARS:
ASTM B-230 – Aluminum Wire 1350-H19 for Electrical Purposes
ASTM B-231 – Concentric-Lay-Stranded Aluminum Conductors
ASTM B-232 – Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
ASTM B-399- Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
ICEA S-61-402-: Thermoplastic-insulated Wire And Cable For The Transmission And Distribution Of Electrical Energy
ICEA S-66-524-XLPE Insulated Wire and Cable For the Transmission and Distribution of Electrical Energy

Specification

Product name: Iec Compact ABC conductor Cable
Voltage: U0/U=0.6/1KV
Technical data: 1. Maximum operating temperature 90 degrees.
2. Maximum short circuit temperature 250 degrees
Application field: 1. Areas where underground networks are expensive.
2. Electrification of rural areas
Road conductor type: 1 AAC: all aluminum bare wire.
Bare conductor of ASC: aluminum strand.
2 AAAC: all aluminum alloy bare conductor.
Bare conductor of AASC: aluminum alloy stranded wire.
3 ACSR: steel core aluminum wire

Packing:

Material:
wooden drum or steel wooden drum
Cable length in each drum: 500m/1000m or as per actual cable length requirements.